Case History No. 20

Gas Recirculation Fan

Inlet Duct Configuration
Turning vanes were installed in the inlet elbow to the I.D. fans to eliminate turbulence and vortex shedding at the fan impeller inlet. Also, inlet box dampers were provided and the outlet dampers were locked in an open position. A further modification included the narrowing of the fan impeller to modify the performance curve so that operation could occur on the right hand side of the peak of the curve. These three combinations of improvement solved the problem totally.