Case History No. 19
In this particular case, control problems were encountered with the lime kiln I.D. fan, and the operators could not obtain adequate air flow through the kiln.

Lime Kiln I.D. Fan

Lime Accumulation in Inlet Box
In this instance, the fan was improperly selected. The fan had considerably excessive volumetric capacity but only marginal pressure capability. Without the ability to develop adequate static pressure, the volume of gas cannot be drafted from the kiln. Because of the incorrect sizing of the fan, the inlet boxes were oversized and the inlet velocity was so low that lime dust dropped out and settled in the inlet box. In this particular instance, the fan housing and impeller required replacement.