Case History No. 18




Industry & Location:
A pulp and paper mill in the northeast

Problem:
Serious noise problems from an I.D. fan on a cogeneration boiler.

Source of Detection:
Complaints from neighbors

Cause of Problem:
This new cogeneration boiler is equipped with an I.D. fan which is turbine driven. The fan is also equipped with inlet box dampers for control purposes. Because of oversizing of the fan, the I.D. fan was initially operated with the inlet dampers in a throttled position and the turbine drive at a reduced speed. The operation of a fan with inlet dampers in a throttled position causes reduced efficiency which customarily develops excessive sound problems.

Solution to Problem:
Reduce the turbine speed and open the inlet dampers

Benefit:
Elimination of sound problem